AVEL Logo
The Power Professionals
  Home Contact Us Toroidal Transformers Power Converters Power Supplies
LC Series DC-DC Power Converters
 

Converter Specifications-LC Series

Input
Voltage, DC

Output
Voltage
(Nominal)

Output
Current

Output
Voltage Regulation

Output
Ripple
(mV)

No-Load
Input
(mA)

Protection
Input/
Output

AVEL P/N

Nominal

Range

Continuous

Max

0-10%

0-100%

12.0

11–15

13.7 ±.2

5A(3)

6A / 30

0.4V

0.2V

<60

<100

A / A

LC100/12/12

12.0

11–15

13.7 ±.2

6A(3)

10A / 15

0.4V

0.2V

<60

<100

A / B

LC100/12/12F

12.0

11–15

13.7 ±.2

12A(3)

20A / 15

0.4V

0.2V

<50

<100

A / C

LC200/12/12

12.0

11–15

24.0 ±.5

2.5A(3)

3A / 30

0.4V

0.2V

<60

<100

A / D

LC100/12/24

12.0

11–15

24.0 ±.5

3A(3)

5A / 15

0.4V

0.2V

<60

<100

A / E

LC100/12/24F

12.0

11–15

24.0 ±.5

6A(3)

10A / 15

0.4V

0.2V

<90

<100

A / F

LC200/12/24

24.0

18–32

13.7 ±.3

2A(3)

7A / 4

0.2V

0.5V

<100

<20

B / B

LC80/24/12

24.0

18–33

13.7 ±.2

6A(3)

10A / 15

0.4V

0.2V

<40

<100

C / B

LC100/24/12

24.0

18–32

13.7 ±.2

12A(3)

20A / 15

0.4V

0.2V

<50

<100

C / C

LC200/24/12

24.0

18–32

24.0 ±.5

3A(3)

5A / 15

0.4V

0.2V

<50

<100

C / E

LC100/24/24

24.0

18–32

24.0 ±.5

6A(3)

10A / 15

0.4V

0.2V

<50

<85

C / F

LC200/24/24

48.0

29–59

24.0 ±.5

2.5A(4)

3A / 30

0.2V

0.1V

<100

<20

B / E

LC80/48/24

48.0

29–59

13.7 ±.3

2A(4)

10A / 4

0.2V

0.5V

<100

<20

B / B

LC80/48/12

48.0

36–54

13.7 ±.2

12A(3)

20A / 15

0.4V

0.2V

<50

<50

D / C

LC200/48/12

48.0

36–54

24.0 ±.5

6A(3)

10A / 15

0.4V

0.2V

<50

<50

D / F

LC200/48/24

  

(1) Maximum current for 1:4 duty cycle, limited to indicated number of minutes.  (2) Percentage of load.  (3) Current at 40șC. (4) Current at 30ș C.
F at end of part number indicates version with flying lead wires (250 mm / 12" long); all other units have 1/4" tabs.

  

Input Protection (in addition to reverse polarity):

A:

Low-voltage switch off at approximately 9.0 V;

High-voltage switch off at approximately 15.0 V.

B:

Low-voltage switch off at approximately 18.0 V.

C:

Low-voltage switch off at approximately 18.0 V;

High-voltage switch off at approximately 34.0.

D:

Low-voltage switch off at approximately 36.0 V;

High-voltage switch off at approximately 68.0.

Output Protection:

A: Electronic fold back current limit at 6.5 A.

B: Electronic fold back current limit at 10.5 A.

C: Electronic fold back current limit at 21 A.

D: Electronic fold back current limit at 3.5 A.

E: Electronic fold back current limit at 5.3 A.

F: Electronic fold back current limit at 11 A.

 
The 100-Watt range LC items are also available resin-filled enclosure for more extreme conditions.  Please contact us for details.