AVEL Logo
The Power Professionals
  Home Contact Us Toroidal Transformers Power Converters Power Supplies
TR Series DC-DC Switching Regulators
 

Switching Regulator Specifications—TR Series

Input
Voltage, DC

Output
Voltage
(Nominal)

Output
Current

Output
Voltage Regulation

Output
Ripple
(mV)

No-Load
Input
(mA)

AVEL P/N

Nominal

Range

Continuous

Max.

0-10%(2)

0-100%(2)

12.0

10–18

24.0 ±.5

5A

12A(1)

0.4

0.2

< 100

8

TR100/12/24

24.0

18-35

13.7 ±.2

8A

8A

0.4

0.1

< 50

4

TR100/24/12

24.0

18-35

13.7 ±.2

16A

16A

0.4

0.1

< 50

8

TR200/24/12

24.0

18-35

13.7 ±.2

25A

25A

0.4

0.1

< 50

8

TR300/24/12

(1) 10 milliseconds.  (2) Percentage of load.
Switch connection: To use remote switch, connect white (remote input) to one side of switch and + (red) lead to other side of switch.
If switch is not required, white (remote input) must be connected to + (red).
Nominal input voltage must be applied to remote switch line to turn unit on.